Network Working Group
Request for Comments: 2954
Obsoletes: 1604
Category: Standards Track
K. Rehbehn
Megisto Systems
D. Fowler
Syndesis Limited
October 2000
Page 1

Definitions of Managed Objects

for Frame Relay Service

Status of this Memo

This document specifies an Internet standards track protocol for the Internet community, and requests discussion and suggestions for improvements. Please refer to the current edition of the "Internet Official Protocol Standards" (STD 1) for the standardization state and status of this protocol. Distribution of this memo is unlimited.

Copyright Notice

Copyright © The Internet Society (2000). All Rights Reserved.

Abstract

This memo defines an extension to the Management Information Base (MIB) for use with network management protocols in Transmission Control Protocol/Internet Protocol-based (TCP/IP) internets. In particular, it defines objects for managing the frame relay service.

This document obsoletes RFC 1604.

Table of Contents

1 The SNMP Management Framework
2 Overview
2.1 Scope of MIB
2.2 Transiting Multiple Frame Relay Networks
2.3 Access Control
2.4 Frame Relay Service MIB Terminology
2.5 Relation to Other MIBs
2.5.1 System Group
2.5.2 Interfaces Table (ifTable, ifXtable)
2.5.3 Stack Table for DS1/E1 Environment
2.5.4 Stack Table for V.35 Environments
2.5.5 The Frame Relay/ATM PVC Service Interworking MIB
2.6 Textual Convention Change
3 Object Definitions
3.1 The Frame Relay Service Logical Port


Page 2

3.2 Frame Relay Management VC Signaling
3.3 Frame Relay PVC End-Points
3.4 Frame Relay PVC Connections
3.5 Frame Relay Accounting
3.6 Frame Relay Network Service Notifications
3.7 Conformance Information
4 Acknowledgments
5 References
6 Security Considerations
7 Authors' Addresses
APPENDIX A Update Information
Intellectual Property Rights
Full Copyright Statement

1 The SNMP Management Framework

The SNMP Management Framework presently consists of five major components:


Page 3

A more detailed introduction to the current SNMP Management Framework can be found in RFC 2570 [16].

Managed objects are accessed via a virtual information store, termed the Management Information Base or MIB. Objects in the MIB are defined using the mechanisms defined in the SMI.

This memo specifies a MIB module that is compliant to the SMIv2. A MIB conforming to the SMIv1 can be produced through the appropriate translations. The resulting translated MIB must be semantically equivalent, except where objects or events are omitted because no translation is possible (use of Counter64). Some machine readable information in SMIv2 will be converted into textual descriptions in SMIv1 during the translation process. However, this loss of machine readable information is not considered to change the semantics of the MIB.

2 Overview

These objects are used to manage a frame relay Service. At present, this applies to the following value of the ifType variable in the IF-MIB [26]:

frameRelayService (44)

This section provides an overview and background of how to use this MIB and other potential MIBs to manage a frame relay service.

2.1 Scope of MIB

The Frame Relay Service MIB supports Customer Network Management (CNM) of a frame relay network service. Through the use of this and other related MIBs, a frame relay service customer's NMS can monitor the customer's UNI/NNI logical ports and PVCs. It provides customers with access to configuration data, performance monitoring information, and fault detection for the delivered frame relay service. As an option, an SNMP agent supporting the Frame Relay Service MIB may allow customer-initiated PVC management operations such as creation, deletion, modification, activation, and deactivation of individual PVCs. However, internal aspects of the network (e.g., switching elements, line cards, and network routing tables) are beyond the scope of this MIB.

The Frame Relay Service MIB models all interfaces and PVCs delivered by a frame relay service within a single virtual SNMP system for the purpose of comprehensively representing the customer's frame relay service. The customer's interfaces and PVCs may physically exist on one or more devices within the network topology. An SNMP agent


Page 4

providing support for the Frame Relay Service MIB as well as other appropriate MIBs to model a single virtual frame relay network service is referred to as a Frame Relay Service (FRS) agent. Internal communication mechanisms between the FRS agent and individual devices within the frame relay network delivering the service are implementation specific and beyond the scope of this MIB.

The customer's NMS will typically access the SNMP agent implementing the Frame Relay Service MIB over a frame relay permanent virtual connection (PVC). SNMP access over a frame relay PVC is achieved through the use of SNMP over UDP over IP encapsulated in Frame Relay according to STD 55, RFC2427 and ITU X.36 Annex D [23]. Alternate access mechanisms and SNMP agent implementations are possible.

This MIB will NOT be implemented on user equipment (e.g., DTE). Such devices are managed using the Frame Relay DTE MIB (RFC2115[18]). However, concentrators may use the Frame Relay Service MIB instead of the Frame Relay DTE MIB.

This MIB does not define managed objects for the physical layer. Existing physical layer MIBs (e.g., DS1 MIB) and Interface MIB will be used as needed in FRS Agent implementations.

This MIB supports frame relay PVCs. This MIB may be extended at a later time to handle frame relay SVCs.

A switch implementation may support this MIB for the purpose of configuration and control of the frame relay service beyond the scope of traditional customer network management applications. A number of objects (e.g. frLportTypeAdmin) support administrative actions that impact the operation of frame relay switch equipment in the network. This is reflected in the differences between the two MIB compliance modules:

The frame relay service compliance module does not support the administrative control objects used for switch management.


Page 5

2.2 Transiting Multiple Frame Relay Networks

This MIB is only used to manage a single frame relay service offering from one network service provider. Therefore, if a customer PVC traverses multiple networks, then the customer must poll a different FRS agent within each frame relay network to retrieve the end-to-end view of service.

Figure 1 illustrates a customer ("User B") NMS accessing FRS agents in three different frame relay networks (I, J, and K).

                +-------------------------------------+
                | Customer Network Management Station |
                |            (SNMP based)             |
                +-------------------------------------+
                    ^              ^               ^
                    |              |               |
                    |              |               |
           UNI      |      NNI     |       NNI     |       UNI
            |       ^       |      ^        |      ^
            | +-----------+ | +-----------+ | +-----------+ |
            | |           | | |           | | |           | |
Originating | | FR | | | FR | | | FR | |Terminating
 +--------+ | | Network I | | | Network J | | | Network K | | +--------+
 |        | | |           | | |           | | |           | | |        |
 |        |---|           |---|           |---|           |---| User B |
 |        | | |           | | |           | | |           | | |        |
 |     ////////////////////////////////////////////////////////////    |
 |        | | |           | | |           | | |           | | |        |
 +--------+ | +-----------+ | +-----------+ | +-----------+ | +--------+
            |               |               |               |
            |               |               |               |
            | PVC Segment 1 | PVC Segment 2 | PVC Segment 3 |
            |<------------->|<------------->|<------------->|
            |                                               |
            |              Multi-network PVC                |
            |<--------------------------------------------->|
            |  NNI = Network-to Network Interface           |
               UNI = User-to-Network Interface

Figure 1, Multi-network PVC

2.3 Access Control

A frame relay network is shared amongst many frame relay subscribers. Each subscriber will only have access to their information (e.g., information with respect to their interfaces and PVCs). The FRS agent should provide instance level granularity for MIB views.


Page 6

2.4 Frame Relay Service MIB Terminology

Access Channel - An access channel generically refers to the DS1/E1 or DS3/E3-based UNI access channel or NNI access channel across which frame relay data transits. An access channel is the access pathway for a single stream of user data.

Within a given DS1 line, an access channel can denote any one of the following:

Within a given E1 line, a channel can denote any one of the following:

Within a given unformatted line, the entire unformatted line is considered an access channel. Examples include RS-232, V.35, V.36 and X.21 (non-switched), and unframed E1 (G.703 without G.704).

Access Rate - The data rate of the access channel, expressed in bits/second. The speed of the user access channel determines how rapidly the end user can inject data into the network.

Bc - The Committed Burst Size (Bc) is the maximum amount of subscriber data (expressed in bits) that the network agrees to transfer, under normal conditions, during a time interval Tc.


Page 7

Be - The Excess Burst Size (Be) is the maximum amount of subscriber data (expressed in bits) in excess of Bc that the network will attempt to deliver during the time interval Tc. This data (Be) is delivered in general with a lower probability than Bc.

CIR - The Committed Information Rate (CIR) is the subscriber data rate (expressed in bits/second) that the network commits to deliver under normal network conditions. CIR is averaged over the time

   interval Tc (CIR = Bc/Tc).

DLCI - Data Link Connection Identifier

Logical Port - This term is used to model the frame relay "interface" on a device.

NNI - Network to Network Interface

Permanent Virtual Connection (PVC) - A virtual connection that has its end-points and bearer capabilities defined at subscription time.

Time slot (E1) - An octet within the 256-bit information field in each E1 frame is defined as a time slot. Time slots are position sensitive within the 256-bit information field. Fractional E1 service is provided in contiguous or non-contiguous time slot increments.

Time slot (DS0) - An octet within the 192-bit information field in each DS1 frame is defined as a time slot. Time slots are position sensitive within the 192-bit information field. Fractional DS1 service is provided in contiguous or non-contiguous time slot increments.

UNI - User to Network Interface

N391 - Full status (status of all PVCs) polling counter

N392 - Error threshold

N393 - Monitored events count

T391 - Link integrity verification polling timer

T392 - Polling verification timer

nT3 - Status enquiry timer

nN3 - Maximum status enquiry counter


Page 8

2.5 Relation to Other MIBs

2.5.1 System Group

Use the System Group of the SNMPv2-MIB [27] to describe the Frame Relay Service (FRS) agent. The FRS agent may be monitoring many frame relay devices in one network. The System Group does not describe frame relay devices monitored by the FRS agent.

sysDescr: ASCII string describing the FRS agent.
Can be up to 255 characters long. This field is generally used to indicate the network providers identification and type of service offered.

sysObjectID: Unique OBJECT IDENTIFIER (OID) for the
FRS agent.

sysUpTime: Clock in the FRS agent; TimeTicks
in 1/100s of a second. Elapsed type since
the FRS agent came on line.

sysContact: Contact for the FRS agent.
ASCII string of up to 255 characters.

sysName: Domain name of the FRS agent, for example,
acme.com

sysLocation: Location of the FRS agent.
ASCII string of up to 255 characters.

sysServices: Services of the managed device. The value "2", which implies that
the frame relay network is providing
a subnetwork level service, is recommended.

2.5.2 Interfaces Table (ifTable, ifXtable)

This specifies how the Interfaces Group defined in the IF MIB [26] shall be used for the management of frame relay based interfaces, and in conjunction with the Frame Relay Service MIB module. This memo assumes the interpretation of the evolution of the Interfaces group to be in accordance with: "The interfaces table (ifTable) contains information on the managed resource's interfaces. Each sub-layer below the internetwork layer of a network interface is considered an interface." Thus, the ifTable allows the following frame relay-based interfaces to be represented as table entries:


Page 9

   -  Frame relay interfaces in equipment (e.g., switches, routers or
      networks) supporting frame relay.  This level is concerned with
      generic frame counts and not with individual virtual connections.

In accordance with the guidelines of ifTable, frame counts per virtual connection are not covered by ifTable, and are considered interface specific and covered in the Frame Relay Service MIB module. In order to interrelate the ifEntries properly, the Interfaces Stack Group shall be supported.

Some specific interpretations of ifTable for frame relay follow.

   Object                 Use for the generic Frame Relay layer
   ======                 =============================================
   ifIndex                Each frame relay port is represented by an
                          ifEntry.

   ifDescr                Description of the frame relay interface.
                          ASCII string describing the UNI/NNI logical
                          port.  Can be up to 255 characters long.

   ifType                 The value allocated for Frame Relay Service
                          is equal to 44.

   ifMtu                  Set to maximum frame size in octets for this
                          frame relay logical port.

   ifSpeed                Peak bandwidth in bits per second available
                          for use. This could be the speed of the
                          logical port and not the access rate. Actual
                          user information transfer rate (i.e., access
                          rate) of the UNI or NNI logical port in bits
                          per second (this is not the clocking speed).
                          For example, it is 1,536,000 bits per second
                          for a DS1-based UNI/NNI logical port and
                          1,984,000 bits per second for an E1-based
                          UNI/NNI logical port.

   ifPhysAddress          The primary address for this logical port
                          assigned by the frame relay interface
                          provider.  An octet string of zero length if
                          no address is used for this logical port.

   ifAdminStatus          The desired administrative status of the
                          frame relay logical port.


Page 10

   ifOperStatus           The current operational status of the Frame
                          Relay UNI or NNI logical port.

   ifLastChange           The value of sysUptime at the last
                          re-initialization of the logical port.  The
                          value of sysUpTime at the time the logical
                          port entered its current operational state.
                          If the current state was entered prior to the
                          last re-initialization of the local network
                          management subsystem, then this object
                          contains a zero value.

   ifInOctets             The number of received octets.  This counter
                          only counts octets from the beginning of the
                          frame relay header field to the end of user
                          data.

   ifInUcastPkts          The number of received unerrored, unicast
                          frames.

   ifInDiscards           The number of received frames discarded.
                          Specifically, frames discarded due to ingress
                          buffer congestion and traffic policing.

   ifInErrors             The number of received frames that are
                          discarded because of an error. Specifically,
                          frames that are too long or too short, frames
                          that are not a multiple of 8 bits in length,
                          frames with an invalid or unrecognized DLCI,
                          frames with an abort sequence, frames with
                          improper flag delimitation, and frame that
                          fail FCS.

   ifInUnknownProtos      The number of packets discarded because of an
                          unknown or unsupported protocol.  For Frame
                          Relay Service interfaces, this counter will
                          always be zero.

   ifOutOctets            The number of transmitted octets.  This
                          counter only counts octets from the beginning
                          of the frame relay header field to the end of
                          user data.

   ifOutUcastpkts         The number of unerrored, unicast frames sent.

   ifOutDiscards          The number of frames discarded in the egress
                          direction. Possible reasons are as follows:
                          policing, congestion.


Page 11

   ifOutErrors            The number of frames discarded in the egress
                          direction because of an error. Specifically,
                          frames that are aborted due to a transmitter
                          underrun.

   ifName                 This variable is not applicable for Frame
                          Relay Service interfaces, therefore, this
                          variable contains a zero-length string.

   ifInMulticastPkts      The number of received unerrored, multicast
                          frames.

   ifInBroadcastPkts      This variable is not applicable for Frame
                          Relay Service interfaces, therefore, this
                          counter is always zero.

   ifOutMulticastPkts     The number of sent unerrored, multicast
                          frames.

   ifOutBroadcastPkts     This variable is not applicable for Frame
                          Relay Service interfaces, therefore, this
                          counter is always zero.

   ifHCInOctets           Only used for DS3-based (and greater) Frame
                          Relay logical ports.  The number of received
                          octets.  This counter only counts octets
                          from the beginning of the frame relay header
                          field to the end of user data.

   ifHCOutOctets          Only used for DS3-based (and greater) Frame
                          Relay logical ports.  The number of
                          transmitted octets.  This counter only counts
                          octets from the beginning of the frame relay
                          header field to the end of user data.

ifLinkUpDownTrapEnable Set to true(1). It is recommended that the underlying physical layer notifications be disabled since both are not required. Notifications are enabled at the frame relay service layer specifically because PVC notifications are not to be sent if the frame relay interface fails. Without a
linkUp/linkDown notification, the management station would receive no notification of the failure.


Page 12

   ifHighSpeed            Set to the user data rate of the frame relay
                          logical port in millions of bits per second.
                          If the user data rate is less than 1 Mbps,
                          then this value is zero.

   ifPromiscuousMode      Set to false(2).

   ifConnectorPresent     Set to false(2).

Frame relay network service interfaces support the Interface Stack Group. Frame relay network service interfaces do not support any other groups or objects in the Interfaces group of the IF MIB.

2.5.3 Stack Table for DS1/E1 Environment

This section describes by example how to use ifStackTable to represent the relationship of frame relay service to ds0 and ds0Bundles with ds1 interfaces [20].

Example: A frame relay service is being carried on 4 ds0s of a ds1.

     +---------------------+
     | Frame Relay Service |
     +---------------------+
                |
     +---------------------+
     | ds0Bundle           |
     +---------------------+
       |     |     |     |
     +---+ +---+ +---+ +---+
     |ds0| |ds0| |ds0| |ds0|
     +---+ +---+ +---+ +---+
       |     |     |     |
     +---------------------+
     | ds1                 |
     +---------------------+

The assignment of the index values could for example be:

ifIndex Description

        1        FrameRelayService (type 44)
        2        ds0Bundle         (type 82)
        3        ds0 #1            (type 81)
        4        ds0 #2            (type 81)
        5        ds0 #3            (type 81)
        6        ds0 #4            (type 81)
        7        ds1               (type 18)


Page 13

The ifStackTable is then used to show the relationships between the various interfaces.

ifStackTable Entries

        HigherLayer   LowerLayer
        0             1
        1             2
        2             3
        2             4
        2             5
        2             6
        3             7
        4             7
        5             7
        6             7
        7             0

In the case where the frame relay service is using a single ds0, then the ds0Bundle is not required.

     +---------------------+
     | Frame Relay Service |
     +---------------------+
       |
     +---+
     |ds0|
     +---+
       |
     +---------------------+
     | ds1                 |
     +---------------------+

The assignment of the index values could for example be:

ifIndex Description

        1        FrameRelayService (type 44)
        2        ds0               (type 81)
        3        ds1               (type 18)

The ifStackTable is then used to show the relationships between the various interfaces.


Page 14

ifStackTable Entries

        HigherLayer   LowerLayer
        0             1
        1             2
        2             3
        3             0

2.5.4 Stack Table for V.35 Environments

This section describes by example how to use ifStackTable to represent the relationship of frame relay service with V.35 interfaces.

        +---------------------+
        | Frame Relay Service |
        +---------------------+
                   |
        +---------------------+
        | v35                 |
        +---------------------+

An example of index values in this case could be:

ifIndex Description

           1        FrameRelayService (type 44)
           2        v35               (type 33)

Note type 33 (RS232-like MIB) is used instead of type 45 (V.35). V35 does not pertain to this environment.

The ifStackTable is then used to show the relationships between the various interfaces.

ifStackTable Entries

           HigherLayer   LowerLayer
           0             1
           1             2
           2             0

2.5.5 The Frame Relay/ATM PVC Service Interworking MIB

Connections between two frame relay endpoints are represented with an entry in the frPVCConnectTable of this MIB. Both endpoints are represented with rows in the frPVCEndptTable. The
frPVCEndptConnectIdentifier object of each endpoint points to the frPVCConnectTable cross-connect table row for the connection.


Page 15

In contrast, a connection that spans frame relay and ATM endpoints is represented with an entry in the frAtmIwfConnectionTable of the FR/ATM PVC Service Interworking MIB defined in [28].

In the case of an inter-worked connection, the
frPVCEndptConnectIdentifier object is set to zero. Instead, the frPVCEndptAtmIwfConnIndex object is set to the index of the FR/ATM IWF cross-connect table row.

The frame relay PVC cross-connect table (frPVCConnectTable) does not contain an entry for the FR/ATM inter-worked connection.

2.6 Textual Convention Change

Version 1 of the Frame Relay Service MIB contains MIB objects defined with the DisplayString textual convention. In version 2 of this MIB, the syntax for these objects has been updated to use the (now preferred) SnmpAdminString textual convention. The new TC provides support for a greater variety of international character sets.

The working group realizes that this change is not strictly supported by SMIv2. In our judgment, the alternative of deprecating the old objects and defining new objects would have a more adverse impact on backward compatibility and interoperability, given the particular semantics of these objects.

3 Object Definitions

FRNETSERV-MIB DEFINITIONS ::= BEGIN

IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
NOTIFICATION-TYPE, transmission,
              Counter32, Integer32             FROM SNMPv2-SMI
              TimeStamp, RowStatus             FROM SNMPv2-TC
              MODULE-COMPLIANCE, OBJECT-GROUP,
              NOTIFICATION-GROUP               FROM SNMPv2-CONF
              InterfaceIndex, ifIndex          FROM IF-MIB
              SnmpAdminString                  FROM SNMP-FRAMEWORK-MIB;

frnetservMIB MODULE-IDENTITY
LAST-UPDATED "200009280000Z" -- September 28, 2000 ORGANIZATION "IETF Frame Relay Service MIB Working Group" CONTACT-INFO
"WG Charter:
http://www.ietf.org/html.charters/frnetmib-charter WG-email:
frnetmib@sunroof.eng.sun.com


Page 16

Subscribe:
frnetmib-request@sunroof.eng.sun.com
Email Archive:
ftp://ftp.ietf.org/ietf-mail-archive/frnetmib

                 Chair:      Andy Malis
                             Vivace Networks, Inc.
                 Email:      Andy.Malis@vivacenetworks.com

WG editor: Kenneth Rehbehn
Megisto Systems, Inc.

                 Email:      krehbehn@megisto.com

Co-author: David Fowler
Syndesis Limited,

                 EMail:      fowler@syndesis.com"

DESCRIPTION
"The MIB module to describe generic objects for Frame Relay Network Service."

            --
            -- Revision History
            --
            REVISION "200009280000Z"
            DESCRIPTION
                 "Published as RFC 2954.

The major new features of this revision include:

Refer to Appendix A for a comprehensive list of changes since RFC 1604."

REVISION "199311161200Z"
DESCRIPTION
"Published as RFC 1604."

            ::= { transmission 44 }


Page 17

frnetservObjects

                OBJECT IDENTIFIER ::= { frnetservMIB 1 }

frnetservTraps

                OBJECT IDENTIFIER ::= { frnetservMIB 2 }

frnetservTrapsPrefix

                OBJECT IDENTIFIER ::= { frnetservTraps 0 }

        --
        -- The Frame Relay Service Logical Port
        --
        frLportTable OBJECT-TYPE
            SYNTAX      SEQUENCE OF FrLportEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The Frame Relay Logical Port Information table is
                    an interface-specific addendum to the generic
                    ifTable of the Interface MIB."
            ::= { frnetservObjects 1 }

frLportEntry OBJECT-TYPE

            SYNTAX      FrLportEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "An entry in the Frame Relay Logical Port
                    Information table."
            INDEX   {   ifIndex }
            ::= { frLportTable 1 }

        FrLportEntry ::=
            SEQUENCE {
                frLportNumPlan            INTEGER,
                frLportContact            SnmpAdminString,
                frLportLocation           SnmpAdminString,
                frLportType               INTEGER,
                frLportAddrDLCILen        INTEGER,
                frLportVCSigProtocol      INTEGER,
                frLportVCSigPointer       OBJECT IDENTIFIER,
                frLportDLCIIndexValue     Integer32,
                frLportTypeAdmin          INTEGER,
                frLportVCSigProtocolAdmin INTEGER,
                frLportFragControl        INTEGER,
                frLportFragSize           Integer32
        }


Page 18

frLportNumPlan OBJECT-TYPE

            SYNTAX      INTEGER {
                        other(1),
                        e164(2),
                        x121(3),
                        none(4)
                        }
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the network
                    address numbering plan for this UNI/NNI logical
                    port. The network address is the object
                    ifPhysAddress. The value none(4) implies that
                    there is no ifPhysAddress.  The FRS agent will
                    return an octet string of zero length for
                    ifPhysAddress.  The value other(1) means that an
                    address has been assigned to this interface, but
                    the numbering plan is not enumerated here."
            REFERENCE   "E.164 [29]
                         X.121 [30]"
            ::= { frLportEntry 1 }

frLportContact OBJECT-TYPE

            SYNTAX      SnmpAdminString
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the network
                    contact for this UNI/NNI logical port."
            ::= { frLportEntry 2 }

frLportLocation OBJECT-TYPE

            SYNTAX      SnmpAdminString
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the frame
                    relay network location for this UNI/NNI logical
                    port."
            ::= { frLportEntry 3 }

        frLportType     OBJECT-TYPE
            SYNTAX      INTEGER {
                        uni(1),
                        nni(2)
                        }
            MAX-ACCESS  read-only


Page 19

            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the type of
                    network interface for this logical port."
            ::= { frLportEntry 4 }

frLportAddrDLCILen OBJECT-TYPE

            SYNTAX      INTEGER {
                        twoOctets10Bits(1),
                        threeOctets10Bits(2),
                        threeOctets16Bits(3),
                        fourOctets17Bits(4),
                        fourOctets23Bits(5)
                        }
            UNITS       "Octets"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the Q.922
                    Address field length and DLCI length for this
                    UNI/NNI logical port."
            REFERENCE   "Q.922 [25]"
            ::= { frLportEntry 5 }

frLportVCSigProtocol OBJECT-TYPE

            SYNTAX      INTEGER {
                        none(1),
                        lmi(2),
                        ansiT1617D(3),
                        ansiT1617B(4),
                        ccittQ933A(5)
                        }
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the Local
                    In-Channel Signaling Protocol that is used for
                    this frame relay UNI/NNI logical port.

                    none(1):        Interface does not use a PVC
                                    signaling protocol

                    lmi(2):         Interface operates the Stratacom/
                                    Nortel/DEC Local Management
                                    Interface Specification protocol

ansiT1617D(3): Interface operates the ANSI T1.617 Annex D PVC status protocol


Page 20

ansiT1617B(4): Interface operates the ANSI

T1.617
Annex B procedures

ccittQ933A(5): Interface operates the ITU Q.933 Annex A PVC status protocol"

              REFERENCE   "LMI [24]
                           T1.617 Annex D [17],
                           Q.933 Annex A [22]"
              ::= { frLportEntry 6 }

frLportVCSigPointer OBJECT-TYPE

            SYNTAX      OBJECT IDENTIFIER
            MAX-ACCESS  read-only
            STATUS      deprecated
            DESCRIPTION
                    "The value of this object is used as a pointer to
                    the table that contains the Local In-Channel
                    Signaling Protocol parameters and errors for this
                    UNI/NNI logical port.

This object has been deprecated to reflect the fact that the local in-channel signaling parameters are accessed from a single table (frMgtVCSigTable) that includes parameters for all possible signaling protocols. Early design anticipated multiple tables, one for each signaling protocol."

            ::= { frLportEntry 7 }

frLportDLCIIndexValue OBJECT-TYPE

            SYNTAX      Integer32 (16..4194303)
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "This object contains a hint to be used for
                    frPVCEndptDLCIIndex when creating entries in the
                    frPVCEndptTable.  The SYNTAX of this object
                    matches the SYNTAX of the frPVCEndptDLCIIndex - an
                    object that is restricted to legal Q.922 DLCI
                    values for the size of the address field.

The value 0 indicates that no unassigned entries are available.

To obtain the frPVCEndptDLCIIndex value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of


Page 21

this object. After each retrieval, the agent must modify the value to the next unassigned index to prevent assignment of the same value to multiple management systems.

A management system should repeat the read to obtain a new value should an attempt to create the new row using the previously returned hint fail."

            REFERENCE   "Q.922 [25]"
            ::= { frLportEntry 8 }

        frLportTypeAdmin   OBJECT-TYPE
            SYNTAX      INTEGER {
                        uni(1),
                        nni(2)
                        }
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object desired identifies the
                    type of network interface for this logical port."
              ::= { frLportEntry 9 }

frLportVCSigProtocolAdmin OBJECT-TYPE

            SYNTAX      INTEGER {
                        none(1),
                        lmi(2),
                        ansiT1617D(3),
                        ansiT1617B(4),
                        ccittQ933A(5)
                        }
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the desired
                    Local In-Channel Signaling Protocol that is used
                    for this frame relay UNI/NNI logical port.  This
                    value must be made the active protocol as soon as
                    possible on the device.

Refer to frLportVCSigProtocol for a description of each signaling protocol choices."

            REFERENCE   "LMI [24]
                         T1.617 Annex D [17],
                         Q.933 Annex A [22]"
            ::= { frLportEntry 10 }

frLportFragControl OBJECT-TYPE


Page 22

            SYNTAX      INTEGER {
                        on(1),
                        off(2)
                        }
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "This object controls the transmission and
                    reception of fragmentation frames for this UNI or
                    NNI interface.

                    on(1)   Frames are fragmented using the interface
                            fragmentation format
                            Note:  The customer side of the interface
                            must also be configured to fragment
                            frames.

off(2) Frames are not fragmented using the interface fragmentation format."

            REFERENCE   "FRF.12 [21]"
            DEFVAL { off }
            ::= { frLportEntry 11 }

frLportFragSize OBJECT-TYPE

            SYNTAX      Integer32 (0..4096)
            UNITS       "Octets"
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object is the size in octets of
                    the maximum size of each fragment to be sent when
                    fragmenting.  This object is only used by the
                    fragmentation transmitter, and the two sides of
                    the interface may differ.  The fragment size
                    includes the octets for the frame relay header,
                    the UI octet, the NLPID, the fragmentation header,
                    and the fragment payload. If frLportFragControl is
                    set to off, this value should be zero."
            REFERENCE   "FRF.12 [21]"
            DEFVAL { 0 }
            ::= { frLportEntry 12 }

        --
        -- Frame Relay Management VC Signaling
        --

frMgtVCSigTable OBJECT-TYPE

            SYNTAX      SEQUENCE OF FrMgtVCSigEntry


Page 23

MAX-ACCESS not-accessible

            STATUS      current
            DESCRIPTION
                    "The Frame Relay Management VC Signaling
                    Parameters and Errors table."
            ::= { frnetservObjects 2 }

frMgtVCSigEntry OBJECT-TYPE

            SYNTAX      FrMgtVCSigEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "An entry in the Frame Relay Management VC
                    Signaling Parameters Errors table."
            INDEX       { ifIndex }
            ::= { frMgtVCSigTable 1 }

        FrMgtVCSigEntry ::=
            SEQUENCE {
                frMgtVCSigProced             INTEGER,
                frMgtVCSigUserN391           INTEGER,
                frMgtVCSigUserN392           INTEGER,
                frMgtVCSigUserN393           INTEGER,
                frMgtVCSigUserT391           INTEGER,
                frMgtVCSigNetN392            INTEGER,
                frMgtVCSigNetN393            INTEGER,
                frMgtVCSigNetT392            INTEGER,
                frMgtVCSigNetnN4             INTEGER,
                frMgtVCSigNetnT3             INTEGER,
                frMgtVCSigUserLinkRelErrors  Counter32,
                frMgtVCSigUserProtErrors     Counter32,
                frMgtVCSigUserChanInactive   Counter32,
                frMgtVCSigNetLinkRelErrors   Counter32,
                frMgtVCSigNetProtErrors      Counter32,
                frMgtVCSigNetChanInactive    Counter32,
                frMgtVCSigProcedAdmin        INTEGER,
                frMgtVCSigUserN391Admin      INTEGER,
                frMgtVCSigUserN392Admin      INTEGER,
                frMgtVCSigUserN393Admin      INTEGER,
                frMgtVCSigUserT391Admin      INTEGER,
                frMgtVCSigNetN392Admin       INTEGER,
                frMgtVCSigNetN393Admin       INTEGER,
                frMgtVCSigNetT392Admin       INTEGER,
                frMgtVCSigNetnT3Admin        INTEGER
        }

frMgtVCSigProced OBJECT-TYPE

            SYNTAX      INTEGER {


Page 24

u2nnet(1),
bidirect(2),
u2nuser(3)
}
MAX-ACCESS read-only

            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the local
                    in-channel signaling procedural role that is used
                    for this UNI/NNI logical port.  Bidirectional
                    procedures implies that both user-side and
                    network-side procedural roles are used.

                    u2nnet(1)   Logical port operates user to network
                                procedure in the role of the network
                                side

bidirect(2) Logical port operates the
bidirectional procedure (both user and network side roles)

u2nuser(3) Logical port operates user to network procedure in the role of the user side"

            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17]"
            ::= { frMgtVCSigEntry 1 }

frMgtVCSigUserN391 OBJECT-TYPE

            SYNTAX      INTEGER (1..255)
            UNITS       "Polls"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the User-side
                    N391 full status polling cycle value for this
                    UNI/NNI logical port.  If the logical port is not
                    performing user-side (bidirectional) procedures,
                    then this object is not instantiated and an
                    attempt to read will result in the noSuchInstance
                    exception response."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17]"
            DEFVAL { 6 }
            ::= { frMgtVCSigEntry 2 }

frMgtVCSigUserN392 OBJECT-TYPE

            SYNTAX      INTEGER (1..10)


Page 25

            UNITS       "Events"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the User-side
                    N392 error threshold value for this UNI/NNI
                    logical port.  If the logical port is not
                    performing user-side (bidirectional) procedures,
                    then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17]"
            DEFVAL { 3 }
            ::= { frMgtVCSigEntry 3 }

frMgtVCSigUserN393 OBJECT-TYPE

            SYNTAX      INTEGER (1..10)
            UNITS       "Events"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the User-side
                    N393 monitored events count value for this UNI/NNI
                    logical port.  If the logical port is not
                    performing user-side (bidirectional) procedures,
                    then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17]"
            DEFVAL { 4 }
            ::= { frMgtVCSigEntry 4 }

frMgtVCSigUserT391 OBJECT-TYPE

            SYNTAX      INTEGER (5..30)
            UNITS       "Seconds"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the User-side
                    T391 link integrity verification polling timer
                    value for this UNI/NNI logical port.  If the
                    logical port is not performing user-side
                    procedures, then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17]"
            DEFVAL { 10 }
            ::= { frMgtVCSigEntry 5 }

frMgtVCSigNetN392 OBJECT-TYPE

            SYNTAX      INTEGER (1..10)


Page 26

            UNITS       "Events"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the Network-
                    side N392 error threshold value (nN2 for LMI) for
                    this UNI/NNI logical port.  If the logical port is
                    not performing network-side procedures, then this
                    object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17],
                         LMI [24]"
            DEFVAL { 3 }
            ::= { frMgtVCSigEntry 6 }

frMgtVCSigNetN393 OBJECT-TYPE

            SYNTAX      INTEGER (1..10)
            UNITS       "Events"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the Network-
                    side N393 monitored events count value (nN3 for
                    LMI) for this UNI/NNI logical port.  If the
                    logical port is not performing network-side
                    procedures, then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17],
                         LMI [24]"
            DEFVAL { 4 }
            ::= { frMgtVCSigEntry 7 }

frMgtVCSigNetT392 OBJECT-TYPE

            SYNTAX      INTEGER (5..30)
            UNITS       "Seconds"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the Network-
                    side T392 polling verification timer value (nT2
                    for LMI)  for this UNI/NNI logical port.  If the
                    logical port is not performing network-side
                    procedures, then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17],
                         LMI [24]"
            DEFVAL { 15 }
            ::= { frMgtVCSigEntry 8 }


Page 27

frMgtVCSigNetnN4 OBJECT-TYPE

            SYNTAX      INTEGER (5..5)
            UNITS       "Events"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the Network-
                    side nN4 maximum status enquires received value
                    for this UNI/NNI logical port.  If the logical
                    port is not performing network-side procedures or
                    is not performing LMI procedures, then this object
                    is not instantiated.

This object applies only to LMI and always has a value of 5."

            REFERENCE   "LMI [24]"
            ::= { frMgtVCSigEntry 9 }

frMgtVCSigNetnT3 OBJECT-TYPE

            SYNTAX      INTEGER (5 | 10 | 15 | 20 | 25 | 30)
            UNITS       "Seconds"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the Network-
                    side nT3 timer (for nN4 status enquires received)
                    value for this UNI/NNI logical port.  If the
                    logical port is not performing network-side
                    procedures or is not performing LMI procedures,
                    then this object is not instantiated.

This object applies only to LMI."

              REFERENCE   "LMI [24]"
              DEFVAL { 20 }
              ::= { frMgtVCSigEntry 10 }

frMgtVCSigUserLinkRelErrors OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Errors"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of user-side local in-channel
                    signaling link reliability errors (i.e., non-
                    receipt of Status/Status Enquiry messages or
                    invalid sequence numbers in a Link Integrity
                    Verification Information Element) for this UNI/NNI
                    logical port.  If the logical port is not


Page 28

performing user-side procedures, then this object is not instantiated."

            ::= { frMgtVCSigEntry 11 }

frMgtVCSigUserProtErrors OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Errors"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of user-side local in-channel
                    signaling protocol errors (i.e., protocol
                    discriminator, unnumbered information, message
                    type, call reference, and mandatory information
                    element errors) for this UNI/NNI logical port. If
                    the logical port is not performing user-side
                    procedures, then this object is not instantiated."
            ::= { frMgtVCSigEntry 12 }

frMgtVCSigUserChanInactive OBJECT-TYPE

          SYNTAX      Counter32
          UNITS       "Events"
          MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of times the user-side channel was
                    declared inactive (i.e., N392 errors in N393
                    events) for this UNI/NNI logical port. If the
                    logical port is not performing user-side
                    procedures, then this object is not instantiated."
            ::= { frMgtVCSigEntry 13 }

frMgtVCSigNetLinkRelErrors OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Errors"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of network-side local in-channel
                    signaling link reliability errors (i.e., non-
                    receipt of Status/Status Enquiry messages or
                    invalid sequence numbers in a Link Integrity
                    Verification Information Element) for this UNI/NNI
                    logical port."
            ::= { frMgtVCSigEntry 14 }

frMgtVCSigNetProtErrors OBJECT-TYPE

            SYNTAX      Counter32


Page 29

            UNITS       "Errors"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of network-side local in-channel
                    signaling protocol errors (i.e., protocol
                    discriminator, message type, call reference, and
                    mandatory information element errors) for this
                    UNI/NNI logical port."
            ::= { frMgtVCSigEntry 15 }

frMgtVCSigNetChanInactive OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Events"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of times the network-side channel was
                    declared inactive (i.e., N392 errors in N393
                    events) for this UNI/NNI logical port."
            ::= { frMgtVCSigEntry 16 }

frMgtVCSigProcedAdmin OBJECT-TYPE

            SYNTAX      INTEGER {
                        u2nnet(1),
                        bidirect(2),
                        u2nuser(3)
                        }
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the local
                    in-channel signaling procedural role that is used
                    for this UNI/NNI logical port.  Bidirectional
                    procedures implies that both user-side and
                    network-side procedural roles are used.

                    u2nnet(1)   Logical port operates user to network
                                procedure in the role of the network
                                side

bidirect(2) Logical port operates the
bidirectional procedure (both user and network side roles)

u2nuser(3) Logical port operates user to network procedure in the role of the user side"


Page 30

            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17]"
            DEFVAL { u2nnet }
            ::= { frMgtVCSigEntry 17 }

frMgtVCSigUserN391Admin OBJECT-TYPE

            SYNTAX      INTEGER (1..255)
            UNITS       "Polls"
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the desired
                    User-side N391 full status polling cycle value for
                    this UNI/NNI logical port.  If the logical port is
                    not performing user-side (bidirectional)
                    procedures, then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17]"
            ::= { frMgtVCSigEntry 18 }

frMgtVCSigUserN392Admin OBJECT-TYPE

            SYNTAX      INTEGER (1..10)
            UNITS       "Events"
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the desired
                    User-side N392 error threshold value for this
                    UNI/NNI logical port.  If the logical port is not
                    performing user-side (bidirectional) procedures,
                    then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17]"
            ::= { frMgtVCSigEntry 19 }

frMgtVCSigUserN393Admin OBJECT-TYPE

            SYNTAX      INTEGER (1..10)
            UNITS       "Events"
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the desired
                    User-side N393 monitored events count value for
                    this UNI/NNI logical port.  If the logical port is
                    not performing user-side (bidirectional)
                    procedures, then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17]"


Page 31

            ::= { frMgtVCSigEntry 20 }

frMgtVCSigUserT391Admin OBJECT-TYPE

            SYNTAX      INTEGER (5..30)
            UNITS       "Seconds"
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the desired
                    User-side T391 link integrity verification polling
                    timer value for this UNI/NNI logical port.  If the
                    logical port is not performing user-side
                    procedures, then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17]"
            ::= { frMgtVCSigEntry 21 }

frMgtVCSigNetN392Admin OBJECT-TYPE

            SYNTAX      INTEGER (1..10)
            UNITS       "Events"
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the desired
                    Network-side N392 error threshold value (nN2 for
                    LMI) for this UNI/NNI logical port.  If the
                    logical port is not performing network-side
                    procedures, then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17],
                         LMI [24]"
            ::= { frMgtVCSigEntry 22 }

frMgtVCSigNetN393Admin OBJECT-TYPE

            SYNTAX      INTEGER (1..10)
            UNITS       "Events"
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the desired
                    Network-side N393 monitored events count value
                    (nN3 for LMI) for this UNI/NNI logical port.  If
                    the logical port is not performing network-side
                    procedures, then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17],
                         LMI [24]"
            ::= { frMgtVCSigEntry 23 }


Page 32

frMgtVCSigNetT392Admin OBJECT-TYPE

            SYNTAX      INTEGER (5..30)
            UNITS       "Seconds"
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the desired
                    Network-side T392 polling verification timer value
                    (nT2 for LMI)  for this UNI/NNI logical port. If
                    the logical port is not performing network-side
                    procedures, then this object is not instantiated."
            REFERENCE   "Q.933 Annex A [22],
                         T1.617 Annex D [17],
                         LMI [24]"
            ::= { frMgtVCSigEntry 24 }

frMgtVCSigNetnT3Admin OBJECT-TYPE

            SYNTAX      INTEGER (5 | 10 | 15 | 20 | 25 | 30)
            UNITS       "Seconds"
            MAX-ACCESS  read-write
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the desired
                    Network-side nT3 timer (for nN4 status enquires
                    received) value for this UNI/NNI logical port. If
                    the logical port is not performing network-side
                    procedures or is not performing LMI procedures,
                    then this object is not instantiated.  This object
                    applies only to LMI."
            REFERENCE   "LMI [24]"
            ::= { frMgtVCSigEntry 25 }

        --
        -- Frame Relay PVC End-points
        --

frPVCEndptTable OBJECT-TYPE

            SYNTAX      SEQUENCE OF FrPVCEndptEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The Frame Relay PVC End-Point table.  This table
                    is used to model a PVC end-point.  This table
                    contains the traffic parameters and statistics for
                    a PVC end-point.

This table is used to identify the traffic parameters for a bi-directional PVC segment end-


Page 33

point, and it also provides statistics for a PVC segment end-point.

A PVC segment end-point is identified by a UNI/NNI logical port index value and DLCI index value.

If the frame relay service provider allows the frame relay CNM subscriber to create, modify or delete PVCs using SNMP, then this table is used to identify and reserve the requested traffic parameters of each PVC segment end-point. The Connection table is used to 'connect' the end- points together. Not all implementations will support the capability of
creating/modifying/deleting PVCs using SNMP as a feature of frame relay CNM service.

Uni-directional PVCs are modeled with zero valued traffic parameters in one of the directions (In or Out direction) in this table.

To create a PVC, the following procedures shall be followed:

1) Create the entries for the PVC segment endpoints in the frPVCEndptTable by specifying the traffic parameters for the bi-directional PVC segment endpoints. As shown in figure 2, a point-to-point PVC has two endpoints, thus two entries in this table. Uni-directional PVCs are modeled with zero valued traffic parameters in one direction; all the `In' direction parameters for one frame relay PVC End-point or all the `Out' direction parameters for the other frame relay PVC Endpoint.

                        In    _____________________________  Out
                       >>>>>>|                             |>>>>>>>>
                       ______|    Frame Relay Network      |________
                        Out  |                             |  In
                       <<<<<<|_____________________________|<<<<<<<<
                     Frame Relay                         Frame Relay
                         PVC                                 PVC
                       Endpoint                            Endpoint

Figure 2, PVC Terminology


Page 34

2) Go to the Frame Relay Connection Group."

            ::= { frnetservObjects 3 }

frPVCEndptEntry OBJECT-TYPE

            SYNTAX      FrPVCEndptEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "An entry in the Frame Relay PVC Endpoint table."
            INDEX   { ifIndex, frPVCEndptDLCIIndex }
            ::= { frPVCEndptTable 1 }

        FrPVCEndptEntry ::=
            SEQUENCE {
                frPVCEndptDLCIIndex            Integer32,
                frPVCEndptInMaxFrameSize       Integer32,
                frPVCEndptInBc                 Integer32,
                frPVCEndptInBe                 Integer32,
                frPVCEndptInCIR                Integer32,
                frPVCEndptOutMaxFrameSize      Integer32,
                frPVCEndptOutBc                Integer32,
                frPVCEndptOutBe                Integer32,
                frPVCEndptOutCIR               Integer32,
                frPVCEndptConnectIdentifier    Integer32,
                frPVCEndptRowStatus            RowStatus,
                frPVCEndptRcvdSigStatus        INTEGER,
                frPVCEndptInFrames             Counter32,
                frPVCEndptOutFrames            Counter32,
                frPVCEndptInDEFrames           Counter32,
                frPVCEndptInExcessFrames       Counter32,
                frPVCEndptOutExcessFrames      Counter32,
                frPVCEndptInDiscards           Counter32,
                frPVCEndptInOctets             Counter32,
                frPVCEndptOutOctets            Counter32,
                frPVCEndptInDiscardsDESet      Counter32,
                frPVCEndptInFramesFECNSet      Counter32,
                frPVCEndptOutFramesFECNSet     Counter32,
                frPVCEndptInFramesBECNSet      Counter32,
                frPVCEndptOutFramesBECNSet     Counter32,
                frPVCEndptInCongDiscards       Counter32,
                frPVCEndptInDECongDiscards     Counter32,
                frPVCEndptOutCongDiscards      Counter32,
                frPVCEndptOutDECongDiscards    Counter32,
                frPVCEndptOutDEFrames          Counter32,
                frPVCEndptAtmIwfConnIndex      Integer32

}


Page 35

frPVCEndptDLCIIndex OBJECT-TYPE

            SYNTAX      Integer32 (16..4194303)
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the DLCI
                    value for this PVC end-point.

The values are restricted to the legal range for the size of address field supported by the logical port (frLportAddrDLCILen)."

            REFERENCE   "Q.922 [25]"
            ::= { frPVCEndptEntry 1 }

frPVCEndptInMaxFrameSize OBJECT-TYPE

            SYNTAX      Integer32 (1..4096)
            UNITS       "Octets"
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "The value of this object is the size in octets of
                    the largest frame relay information field for this
                    PVC end-point in the ingress direction (into the
                    frame relay network).  The value of
                    frPVCEndptInMaxFrameSize must be less than or
                    equal to the corresponding ifMtu for this frame
                    relay UNI/NNI logical port."
            REFERENCE   "FRF.1 [31]
                         Q.922 [25]
                         Q.933 [22]"
            DEFVAL { 1600 }
            ::= { frPVCEndptEntry 2 }

frPVCEndptInBc OBJECT-TYPE

            SYNTAX      Integer32 (1..2147483647)
            UNITS       "Bits"
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the
                    committed burst size (Bc) parameter (measured in
                    bits) for this PVC end-point in the ingress
                    direction (into the frame relay network).

Note that the max value of this range is lower than the max value allowed by Q.933 (16383 * 10**6).


Page 36

Note that the value is encoded in bits whilst the Q.933 Link layer core parameters information element encodes this information using octet units."

            REFERENCE   "Q.933 [22]"
            ::= { frPVCEndptEntry 3 }

frPVCEndptInBe OBJECT-TYPE

            SYNTAX      Integer32 (1..2147483647)
            UNITS       "Bits"
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the excess
                    burst size (Be) parameter (measured in bits) for
                    this PVC end-point in the ingress direction (into
                    the frame relay network).

Note that the max value of this range is lower than the max value allowed by Q.933 (16383 * 10**6).

Note that the value is encoded in bits whilst the Q.933 Link layer core parameters information element encodes this information using octet units."

            REFERENCE   "Q.933 [22]"
            ::= { frPVCEndptEntry 4 }

frPVCEndptInCIR OBJECT-TYPE

            SYNTAX      Integer32 (1..2147483647)
            UNITS       "Bits per Second"
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the
                    committed information rate (CIR) parameter
                    (measured in bits per second) for this PVC end-
                    point in the ingress direction (into the frame
                    relay network).

Note that the max value of this range is lower than the max value allowed by Q.933 (2047 * 10**6)."

            REFERENCE   "Q.933 [22]"
            ::= { frPVCEndptEntry 5 }

frPVCEndptOutMaxFrameSize OBJECT-TYPE


Page 37

            SYNTAX      Integer32 (1..4096)
            UNITS       "Octets"
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "The value of this object is the size in octets of
                    the largest frame relay information field for this
                    PVC end-point in the egress direction (out of the
                    frame relay network).  The value of
                    frPVCEndptOutMaxFrameSize must be less than or
                    equal to the corresponding ifMtu for this frame
                    relay UNI/NNI logical port."
            REFERENCE   "FRF.1 [31]
                         Q.922 [25]
                         Q.933 [22]"
            DEFVAL { 1600 }
            ::= { frPVCEndptEntry 6 }

frPVCEndptOutBc OBJECT-TYPE

            SYNTAX      Integer32 (1..2147483647)
            UNITS       "Bits"
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the
                    committed burst size (Bc) parameter (measured in
                    bits) for this PVC end-point in the egress
                    direction (out of the frame relay network).

Note that the max value of this range is lower than the max value allowed by Q.933 (16383 * 10**6).

Note that the value is encoded in bits whilst the Q.933 Link layer core parameters information element encodes this information using octet units."

            REFERENCE   "Q.933 [22]"
            ::= { frPVCEndptEntry 7 }

frPVCEndptOutBe OBJECT-TYPE

            SYNTAX      Integer32 (1..2147483647)
            UNITS       "Bits"
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the excess
                    burst size (Be) parameter (measured in bits) for


Page 38

this PVC end-point in the egress direction (out of the frame relay network).

Note that the max value of this range is lower than the max value allowed by Q.933 (16383 * 10**6).

Note that the value is encoded in bits whilst the Q.933 Link layer core parameters information element encodes this information using octet units."

            REFERENCE   "Q.933 [22]"
            ::= { frPVCEndptEntry 8 }

frPVCEndptOutCIR OBJECT-TYPE

            SYNTAX      Integer32 (1..2147483647)
            UNITS       "Bits per Second"
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the
                    committed information rate (CIR) parameter
                    (measured in bits per second) for this PVC end-
                    point in the egress direction (out of the frame
                    relay network).

Note that the max value of this range is lower than the max value allowed by Q.933 (2047 * 10**6)."

            REFERENCE   "Q.933 [22]"
            ::= { frPVCEndptEntry 9 }

frPVCEndptConnectIdentifier OBJECT-TYPE

            SYNTAX      Integer32 (0..2147483647)
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "This object is used to associate PVC end-points
                    as being part of one PVC segment connection. This
                    value of this object is equal to the value of
                    frPVCConnectIndex, which is used as one of the
                    indices into the frPVCConnectTable.

A connection that has been cross-connected via the FR/ATM PVC Service IWF cross-connect table will return the value zero when this object is read. In case of these interworked connections, the frPVCEndptAtmIwfConnIndex object must be accessed


Page 39

to select the entry in the FR/ATM PVC Service IWF cross-connect table.

The value of this object is provided by the agent, after the associated entries in the
frPVCConnectTable or frAtmIwfConnectionTable have been created."

            ::= { frPVCEndptEntry 10 }

frPVCEndptRowStatus OBJECT-TYPE

            SYNTAX      RowStatus
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "This object is used to create new rows in this
                    table, modify existing rows, and to delete
                    existing rows.  To create a new PVC, the entries
                    for the PVC segment end-points in the
                    frPVCEndptTable must first be created.  Next, the
                    frPVCConnectTable is used to associate the frame
                    relay PVC segment end-points.  In order for the
                    manager to have the necessary error diagnostics,
                    the frPVCEndptRowStatus object must initially be
                    set to `createAndWait(5)'.  While the
                    frPVCEndptRowStatus object is in the
                    `createAndWait(5)' state, the manager can set each
                    columnar object and get the necessary error
                    diagnostics.  The frPVCEndptRowStatus object may
                    not be set to `active(1)' unless the following
                    columnar objects exist in this row:
                    frPVCEndptInMaxFrameSize, frPVCEndptInBc,
                    frPVCEndptInBe, frPVCEndptInCIR,
                    frPVCEndptOutMaxFrameSize, frPVCEndptOutBc,
                    frPVCEndptOutBe, and frPVCEndptOutCIR."
            ::= { frPVCEndptEntry 11 }

frPVCEndptRcvdSigStatus OBJECT-TYPE

            SYNTAX      INTEGER {
                        deleted(1),
                        active(2),
                        inactive(3),
                        none(4)
                        }
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the PVC
                    status received via the local in-channel signaling


Page 40

procedures for this PVC end-point. This object is only pertinent for interfaces that perform the bidirectional procedures.

Each value has the following meaning:
deleted(1): This PVC is not listed in the full status reports received from the user device. The object retains this value for as long as the PVC is not listed in the full status reports

                    active(2):   This PVC is reported as active, or
                                   operational, by the user device.

inactive(3): This PVC is reported as inactive, or non-operational, by the user device.

                      none(4):     This interface is only using the
                                   network-side in-channel signaling
                                   procedures, so this object does
                                   not apply."
            ::= { frPVCEndptEntry 12 }

frPVCEndptInFrames OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames received by the network
                    (ingress) for this PVC end-point. This includes
                    any frames discarded by the network due to
                    submitting more than Bc + Be data or due to any
                    network congestion recovery procedures."
            ::= { frPVCEndptEntry 13 }

frPVCEndptOutFrames OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames sent by the network (egress)
                    regardless of whether they are Bc or Be frames for
                    this PVC end-point."
            ::= { frPVCEndptEntry 14 }


Page 41

frPVCEndptInDEFrames OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames received by the network
                    (ingress) with the DE bit set to (1) for this PVC
                    end-point."
            ::= { frPVCEndptEntry 15 }

frPVCEndptInExcessFrames OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames received by the network
                    (ingress) for this PVC end-point which were
                    treated as excess traffic.  Frames which are sent
                    to the network with DE set to zero are treated as
                    excess when more than Bc bits are submitted to the
                    network during the Committed Information Rate
                    Measurement Interval (Tc).  Excess traffic may or
                    may not be discarded at the ingress if more than
                    Bc + Be bits are submitted to the network during
                    Tc.  Traffic discarded at the ingress is not
                    recorded in frPVCEndptInExcessFrames.  Frames
                    which are sent to the network with DE set to one
                    are also treated as excess traffic."
            ::= { frPVCEndptEntry 16 }

frPVCEndptOutExcessFrames OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames sent by the network (egress)
                    for this PVC end-point which were treated as
                    excess traffic.  (The DE bit may be set to one.)"
            ::= { frPVCEndptEntry 17 }

frPVCEndptInDiscards OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current


Page 42

DESCRIPTION
"The number of frames received by the network (ingress) that were discarded due to traffic enforcement for this PVC end-point. Congestion discards are not counted in this object."

            ::= { frPVCEndptEntry 18 }

frPVCEndptInOctets OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Octets"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of octets received by the network
                    (ingress) for this PVC end-point.  This counter
                    should only count octets from the beginning of the
                    frame relay header field to the end of user data.
                    If the network supporting frame relay can not
                    count octets, then this count should be an
                    approximation."
            ::= { frPVCEndptEntry 19 }

frPVCEndptOutOctets OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Octets"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of octets sent by the network (egress)
                    for this PVC end-point.  This counter should only
                    count octets from the beginning of the frame relay
                    header field to the end of user data.  If the
                    network supporting frame relay can not count
                    octets, then this count should be an
                    approximation."
            ::= { frPVCEndptEntry 20 }

frPVCEndptInDiscardsDESet OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames received by the network
                    (ingress) that were discarded with the DE bit set
                    due to traffic enforcement for this PVC end-point.
                    Congestion discards are not counted in this
                    object."


Page 43

            ::= { frPVCEndptEntry 21 }

frPVCEndptInFramesFECNSet OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames received by the network
                    (ingress) that have the FECN bit set for this PVC
                    end-point."
            ::= { frPVCEndptEntry 22 }

frPVCEndptOutFramesFECNSet OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames sent by the network (egress)
                    that have the FECN bit set for this PVC end-
                    point."
            ::= { frPVCEndptEntry 23 }

frPVCEndptInFramesBECNSet OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames received by the network
                    (ingress) that have the BECN bit set for this PVC
                    end-point."
            ::= { frPVCEndptEntry 24 }

frPVCEndptOutFramesBECNSet OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames sent by the network (egress)
                    that have the BECN bit set for this PVC end-
                    point."
            ::= { frPVCEndptEntry 25 }

frPVCEndptInCongDiscards OBJECT-TYPE

            SYNTAX      Counter32


Page 44

            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames received by the network
                    (ingress) that were discarded due to input buffer
                    congestion, rather than traffic enforcement, for
                    this PVC end-point."
            ::= { frPVCEndptEntry 26 }

frPVCEndptInDECongDiscards OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames counted by
                    frPVCEndptInCongDiscards with the DE bit set to
                    (1)."
            ::= { frPVCEndptEntry 27 }

frPVCEndptOutCongDiscards OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames sent by the network (egress)
                    that were discarded due to output buffer
                    congestion for this PVC end-point."
            ::= { frPVCEndptEntry 28 }

frPVCEndptOutDECongDiscards OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The number of frames counted by
                    frPVCEndptOutCongDiscards with the DE bit set to
                    (1)."
            ::= { frPVCEndptEntry 29 }

frPVCEndptOutDEFrames OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Frames"
            MAX-ACCESS  read-only
            STATUS      current


Page 45

DESCRIPTION
"The number of frames sent by the network (egress) with the DE bit set to (1) for this PVC end- point."

            ::= { frPVCEndptEntry 30 }

frPVCEndptAtmIwfConnIndex OBJECT-TYPE

            SYNTAX      Integer32  (0..2147483647)
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "This object contains the index value of the
                    FR/ATM cross-connect table entry used to link the
                    frame relay PVC with an ATM PVC.

Each row of the frPVCEndptTable that is not cross-connected with an ATM PVC must return the value zero when this object is read.

The value of this object is initialized by the agent after the associated entries in the frAtmIwfConnectionTable have been created.

The value of this object is reset to zero following destruction of the associated entry in the frAtmIwfConnectionTable"

            ::= { frPVCEndptEntry 31 }

        --
        -- Frame Relay PVC Connections
        --

frPVCConnectIndexValue OBJECT-TYPE

            SYNTAX      INTEGER (0..2147483647)
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "This object returns a hint to be used for
                    frPVCConnectIndex when creating entries in the
                    frPVCConnectTable.

The value 0 indicates that no unassigned entries are available.

To obtain the frPVCConnectIndex value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of this object. After each retrieval, the agent must


Page 46

modify the value to the next unassigned index to prevent assignment of the same value to multiple management systems.

A management system should repeat the read to obtain a new value should an attempt to create the new row using the previously returned hint fail."

            ::= { frnetservObjects 4 }

frPVCConnectTable OBJECT-TYPE

            SYNTAX      SEQUENCE OF FrPVCConnectEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The Frame Relay PVC Connect Table is used to
                    model the bi-directional PVC segment flows
                    including:  point-to-point PVCs, point-to-
                    multipoint PVCs, and multipoint-to-multipoint
                    PVCs.

This table has read-create access and is used to associate PVC end-points together as belonging to one connection. The frPVCConnectIndex is used to associate all the bi-directional flows. Not all implementations will support the capability of creating/modifying/deleting PVCs using SNMP as a feature of frame relay CNM service.

Once the entries in the frPVCEndptTable are created, the following step are used to associate the PVC end-points as belonging to one PVC connection:

1) Obtain a unique frPVCConnectIndex
using the frPVCConnectIndexValue object.

2) Connect the PVC segment endpoints together with the applicable frPVCConnectIndex value obtained via frPVCConnectIndexValue. The entries in this table are created by using the frPVCConnectRowStatus object.

3) The agent will provide the value of the corresponding instances of
frPVCEndptConnectIdentifier with the frPVCConnectIndex value.

4) Set frPVCConnectAdminStatus to `active(1)' in


Page 47

all rows for this PVC segment to turn the PVC on.

For example, the Frame Relay PVC Connection Group models a bi-directional, point-to-point PVC segment as one entry in this table.

                    Frame Relay                           Frame Relay
                     Network                                 Network
                     Low Port                               High Port
                             __________________________________
                            |                                  |
                       _____| >> from low to high PVC flow  >> |_____
                            | << from high to low PVC flow  << |
                            |__________________________________|

The terms low and high are chosen to represent numerical ordering of a PVC segment's endpoints for representation in this table. That is, the endpoint with the lower value of ifIndex is termed 'low', while the opposite endpoint of the segment is termed 'high'. This terminology is to provide directional information; for example the frPVCConnectL2hOperStatus and
frPVCConnectH2lOperStatus as illustrated above.

If the Frame Relay Connection table is used to model a unidirectional PVC, then one direction (either from low to high or from high to low) has its Operational Status equal to down.

A PVC segment is a portion of a PVC that traverses one Frame Relay Network, and a PVC segment is identified by its two end-points (UNI/NNI logical port index value and DLCI index value) through one Frame Relay Network."

            ::= { frnetservObjects 5 }

frPVCConnectEntry OBJECT-TYPE

            SYNTAX      FrPVCConnectEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "An entry in the Frame Relay PVC Connect table.
                    This entry is used to model a PVC segment in two
                    directions."
            INDEX { frPVCConnectIndex,
                    frPVCConnectLowIfIndex,


Page 48

frPVCConnectLowDLCIIndex,
frPVCConnectHighIfIndex,
frPVCConnectHighDLCIIndex }

            ::= { frPVCConnectTable 1 }

        FrPVCConnectEntry ::=
            SEQUENCE {
                frPVCConnectIndex            Integer32,
                frPVCConnectLowIfIndex       InterfaceIndex,
                frPVCConnectLowDLCIIndex     Integer32,
                frPVCConnectHighIfIndex      InterfaceIndex,
                frPVCConnectHighDLCIIndex    Integer32,
                frPVCConnectAdminStatus      INTEGER,
                frPVCConnectL2hOperStatus    INTEGER,
                frPVCConnectH2lOperStatus    INTEGER,
                frPVCConnectL2hLastChange    TimeStamp,
                frPVCConnectH2lLastChange    TimeStamp,
                frPVCConnectRowStatus        RowStatus,
                frPVCConnectUserName         SnmpAdminString,
                frPVCConnectProviderName     SnmpAdminString
        }

frPVCConnectIndex OBJECT-TYPE

              SYNTAX      Integer32 (0..2147483647)
              MAX-ACCESS  not-accessible
              STATUS      current
              DESCRIPTION
                      "The value of this object is equal to the
                      frPVCConnectIndexValue obtained to uniquely
                      identify this PVC segment connection."
              ::= { frPVCConnectEntry 1 }

frPVCConnectLowIfIndex OBJECT-TYPE

            SYNTAX      InterfaceIndex
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to IF-MIB
                    ifIndex value of the UNI/NNI logical port for this
                    PVC segment.  The term low implies that this PVC
                    segment end-point has the numerically lower
                    ifIndex value than the connected/associated PVC
                    segment end-point.

RFC 1604 permitted a zero value for this object to identify termination at a non-frame relay interface. However, this cross-connect table is limited to frame relay connections. See the frame


Page 49

relay/ATM IWF MIB [28] for the cross-connect table used for those types of connections."

            ::= { frPVCConnectEntry 2 }

frPVCConnectLowDLCIIndex OBJECT-TYPE

            SYNTAX      Integer32 (16..4194303)
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the DLCI
                    value for this end-point of the PVC segment."
            REFERENCE   "Q.922 [25]"
            ::= { frPVCConnectEntry 3 }

frPVCConnectHighIfIndex OBJECT-TYPE

            SYNTAX      InterfaceIndex
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to IF-MIB
                    ifIndex value for the UNI/NNI logical port for
                    this PVC segment.  The term high implies that this
                    PVC segment end-point has the numerically higher
                    ifIndex value than the connected/associated PVC
                    segment end-point."
            ::= { frPVCConnectEntry 4 }

frPVCConnectHighDLCIIndex OBJECT-TYPE

            SYNTAX      Integer32 (16..4194303)
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the egress
                    DLCI value for this end-point of the PVC segment."
            REFERENCE   "Q.922 [25]"
            ::= { frPVCConnectEntry 5 }

frPVCConnectAdminStatus OBJECT-TYPE

            SYNTAX      INTEGER {
                        active(1),
                        inactive(2),
                        testing(3)
                        }
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the desired
                    administrative status of this bi-directional PVC


Page 50

segment. The active(1) state means the PVC segment is currently operational; the inactive(2) state means the PVC segment is currently not operational; the testing(3) state means the PVC segment is currently undergoing a test. This state is set by an administrative entity. This value affects the PVC status indicated across the ingress NNI/UNI of both end-points of the bi- directional PVC segment. When a PVC segment connection is created using this table, this object is initially set to `inactive(2)'. After the frPVCConnectRowStatus object is set to `active(1)' (and the corresponding/associated entries in the frPVCEndptTable have their frPVCEndptRowStatus object set to `active(1)'), the frPVCConnectAdminStatus object may be set to `active(1)' to turn on the PVC segment
connection."

            ::= { frPVCConnectEntry 6 }

frPVCConnectL2hOperStatus OBJECT-TYPE

            SYNTAX      INTEGER {
                        active(1),
                        inactive(2),
                        testing(3),
                        unknown(4)
                        }
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the current
                    operational status of the PVC segment connection
                    in one direction; (i.e., in the low to high
                    direction). This value affects the PVC status
                    indicated across the ingress NNI/UNI (low side) of
                    the PVC segment.

The values mean:

                    active(1)   - PVC is currently operational

inactive(2) - PVC is currently not operational. This may be because of an underlying LMI or DS1 failure.

testing(3) - PVC is currently undergoing a test. This may be because of an underlying frLport or DS1 undergoing a test.


Page 51

unknown(4) - the status of the PVC currently can not be determined."

            ::= { frPVCConnectEntry 7 }

frPVCConnectH2lOperStatus OBJECT-TYPE

            SYNTAX      INTEGER {
                        active(1),
                        inactive(2),
                        testing(3),
                        unknown(4)
                        }
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object identifies the current
                    operational status of the PVC segment connection
                    in one direction; (i.e., in the high to low
                    direction)..  This value affects the PVC status
                    indicated across the ingress NNI/UNI (high side)
                    of the PVC segment.

The values mean:

                    active(1)   - PVC is currently operational

inactive(2) - PVC is currently not operational. This may be because of an underlying LMI or DS1 failure.

testing(3) - PVC is currently undergoing a test. This may be because of an underlying frLport or DS1 undergoing a test.

unknown(4) - the status of the PVC currently can not be determined."

            ::= { frPVCConnectEntry 8 }

frPVCConnectL2hLastChange OBJECT-TYPE

            SYNTAX      TimeStamp
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of the Interface MIB's sysUpTime object
                    at the time this PVC segment entered its current
                    operational state in the low to high direction.
                    If the current state was entered prior to the last
                    re-initialization of the FRS agent, then this
                    object contains a zero value."


Page 52

            ::= { frPVCConnectEntry 9 }

frPVCConnectH2lLastChange OBJECT-TYPE

            SYNTAX      TimeStamp
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of the Interface MIB's sysUpTime object
                    at the time this PVC segment entered its current
                    operational state in the high to low direction.
                    If the current state was entered prior to the last
                    re-initialization of the FRS agent, then this
                    object contains a zero value."
            ::= { frPVCConnectEntry 10 }

frPVCConnectRowStatus OBJECT-TYPE

            SYNTAX      RowStatus
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "The status of this entry in the
                    frPVCConnectTable.  This variable is used to
                    create new connections for the PVC end-points and
                    to change existing connections of the PVC end-
                    points.  This object must be initially set to
                    `createAndWait(5)'. In this state, the agent
                    checks the parameters in the associated entries in
                    the frPVCEndptTable to verify that the PVC end-
                    points can be connected (i.e., the In parameters
                    for one PVC end-point are equal to the Out
                    parameters for the other PVC end-point).  This
                    object can not be set to `active(1)' unless the
                    following columnar object exists in this row:
                    frPVCConnectAdminStatus.  The agent also supplies
                    the associated value of frPVCConnectIndex for the
                    frPVCEndptConnectIdentifier instances.  To turn on
                    a PVC segment connection, the
                    frPVCConnectAdminStatus is set to `active(1)'."
            ::= { frPVCConnectEntry 11 }

frPVCConnectUserName OBJECT-TYPE

            SYNTAX      SnmpAdminString
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "This is a service user assigned textual
                    representation of a PVC."
            ::= { frPVCConnectEntry 12 }


Page 53

frPVCConnectProviderName OBJECT-TYPE

            SYNTAX      SnmpAdminString
            MAX-ACCESS  read-create
            STATUS      current
            DESCRIPTION
                    "This is a system supplied textual representation
                    of PVC.  It is assigned by the service provider."
            ::= { frPVCConnectEntry 13 }

        --
        -- The Frame Relay Accounting
        --

frAccountPVCTable OBJECT-TYPE

            SYNTAX      SEQUENCE OF FrAccountPVCEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The Frame Relay Accounting PVC table.  This table
                    is used to perform accounting on a PVC segment
                    end-point basis."
            ::= { frnetservObjects 6 }

frAccountPVCEntry OBJECT-TYPE

            SYNTAX      FrAccountPVCEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "An entry in the Frame Relay Accounting PVC
                    table."
            INDEX   {   ifIndex,
                        frAccountPVCDLCIIndex }
            ::= { frAccountPVCTable 1 }

        FrAccountPVCEntry ::=
            SEQUENCE {
                frAccountPVCDLCIIndex            Integer32,
                frAccountPVCSegmentSize          Integer32,
                frAccountPVCInSegments           Counter32,
                frAccountPVCOutSegments          Counter32
            }

frAccountPVCDLCIIndex OBJECT-TYPE

            SYNTAX      Integer32 (16..4194303)
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the DLCI


Page 54

value for this PVC segment end-point."

            REFERENCE   "Q.922 [25]"
            ::= { frAccountPVCEntry 1 }

frAccountPVCSegmentSize OBJECT-TYPE

            SYNTAX      Integer32
            UNITS       "Octets"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the Segment
                    Size for this PVC segment end-point."
            ::= { frAccountPVCEntry 2 }

frAccountPVCInSegments OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Segments"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the number
                    of segments received by this PVC segment end-
                    point."
            ::= { frAccountPVCEntry 3 }

frAccountPVCOutSegments OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Segments"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the number
                    of segments sent by this PVC segment end-point."
            ::= { frAccountPVCEntry 4 }

        --
        -- Accounting on a Frame Relay Logical Port
        --

frAccountLportTable OBJECT-TYPE

            SYNTAX      SEQUENCE OF FrAccountLportEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "The Frame Relay Accounting Logical Port table.
                    This table is used to perform accounting on a
                    UNI/NNI Logical Port basis."
            ::= { frnetservObjects 7 }


Page 55

frAccountLportEntry OBJECT-TYPE

            SYNTAX      FrAccountLportEntry
            MAX-ACCESS  not-accessible
            STATUS      current
            DESCRIPTION
                    "An entry in the Frame Relay Accounting Logical
                    Port table."
            INDEX   {   ifIndex }
            ::= { frAccountLportTable 1 }

        FrAccountLportEntry ::=
            SEQUENCE {
                frAccountLportSegmentSize
                    Integer32,
                frAccountLportInSegments
                    Counter32,
                frAccountLportOutSegments
                    Counter32
            }

frAccountLportSegmentSize OBJECT-TYPE

            SYNTAX      Integer32
            UNITS       "Octets"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the Segment
                    Size for this UNI/NNI logical port."
            ::= { frAccountLportEntry 1 }

frAccountLportInSegments OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Segments"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the number
                    of segments received by this UNI/NNI logical
                    port."
            ::= { frAccountLportEntry 2 }

frAccountLportOutSegments OBJECT-TYPE

            SYNTAX      Counter32
            UNITS       "Segments"
            MAX-ACCESS  read-only
            STATUS      current
            DESCRIPTION
                    "The value of this object is equal to the number


Page 56

of segments sent by this UNI/NNI logical port."

            ::= { frAccountLportEntry 3 }

          --
          -- Frame Relay Network Service Notifications
          --

frPVCConnectStatusChange NOTIFICATION-TYPE
OBJECTS { frPVCConnectIndex,
frPVCConnectLowIfIndex,
frPVCConnectLowDLCIIndex,
frPVCConnectHighIfIndex,
frPVCConnectHighDLCIIndex,
frPVCConnectL2hOperStatus,
frPVCConnectH2lOperStatus,
frPVCEndptRcvdSigStatus }
STATUS deprecated
DESCRIPTION
"Refer to the description of the
frPVCConnectStatusNotif notification that has replaced this notification. The notification is deprecated due to the incorrect inclusion of index values and to take advantage of the trap prefix for automatic conversion from SMIv2 to SMIv1 by making the one but last sub-ID a zero (i.e. the so-called trap prefix)."

            ::= { frnetservTraps 1 }

frPVCConnectStatusNotif NOTIFICATION-TYPE
OBJECTS { frPVCConnectL2hOperStatus,
frPVCConnectH2lOperStatus,
frPVCEndptRcvdSigStatus }
STATUS current
DESCRIPTION
"This notification indicates that the indicated PVC has changed state.

This notification is not sent if an FR-UNI changes state; a linkDown or linkUp notification should be sent instead. The first instance of
frPVCEndptRcvdSigStatus is for the endpoint with LowIfIndex, LowDLCIIndex. The second instance of frPVCEndptRcvdSigStatus is for the endpoint with HighIfIndex, HighDLCIIndex"

            ::= { frnetservTrapsPrefix 2 }

        -- Conformance Information


Page 57

frnetservConformance OBJECT IDENTIFIER

            ::= { frnetservMIB 3 }

        frnetservGroups       OBJECT IDENTIFIER
            ::= { frnetservConformance 1 }
        frnetservCompliances  OBJECT IDENTIFIER
            ::= { frnetservConformance 2 }

        --
        --  Service (Read-only) Modules
        --
        frnetservCompliance2 MODULE-COMPLIANCE
            STATUS      current
            DESCRIPTION
                    "The compliance statement for SNMP entities which
                    have Frame Relay Network Service Interfaces.

The distinction between 'service' and 'switch' is that a 'switch' is configured via this MIB. Hence, the various read/write objects have write capability. A 'service' represents a passive monitor-only customer network management interface. The various read/write objects are restricted to read-only capability."
MODULE -- this module
MANDATORY-GROUPS { frnetservLportGroup2,
frnetservMgtVCSigGroup,
frnetservPVCEndptGroup,
frnetservPVCEndptGroup2,
frnetservPVCConnectGroup, frnetservPVCConnectNamesGroup, frnetservPVCNotifGroup2 }

                GROUP       frnetservAccountPVCGroup
                DESCRIPTION
                    "This group is optional for frame relay
                    interfaces.  It is mandatory if and only if
                    accounting is performed on a PVC basis this frame
                    relay interface."
                GROUP       frnetservAccountLportGroup
                DESCRIPTION
                    "This group is optional for frame relay
                    interfaces.  It is mandatory if and only if
                    accounting is performed on a logical port basis
                    this frame relay interface."

                OBJECT      frPVCEndptInMaxFrameSize


Page 58

MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."

                OBJECT      frPVCEndptInBc
                MIN-ACCESS  read-only
                DESCRIPTION
                      "Write access is not required."

                OBJECT      frPVCEndptInBe
                MIN-ACCESS  read-only
                DESCRIPTION
                      "Write access is not required."

                OBJECT      frPVCEndptInCIR
                MIN-ACCESS  read-only
                DESCRIPTION
                      "Write access is not required."

                OBJECT      frPVCEndptOutMaxFrameSize
                MIN-ACCESS  read-only
                DESCRIPTION
                      "Write access is not required."

                OBJECT      frPVCEndptOutBc
                MIN-ACCESS  read-only
                DESCRIPTION
                      "Write access is not required."

                OBJECT      frPVCEndptOutBe
                MIN-ACCESS  read-only
                DESCRIPTION
                      "Write access is not required."

                OBJECT      frPVCEndptOutCIR
                MIN-ACCE